97国产午夜视频在线观看_欧美精品日韩精品国产精品_国产亚洲欧美一区在线观看_日韩精品无码A∨中文无码版_精品九九99久久_亚洲经典日韩欧美国产一区_2022国产高清无码在线观看_丰满少妇被猛烈进入流水_在线观看丝袜AV黄色_欧美大片一区二区视频在线

Popular searches: YG028 Computer type Electronic universal testing machine
Positon: Home>Products
Products
YG135C-Ⅱ type electronic evenness tester
YG135C-Ⅱ type electronic evenness tester

The measuring instrument is suitable for the textile industry, cotton, wool, linen, silk, chemical staple fiber linear density of pure spinning or blended lines and uneven uneven structure and characteristics of the textile industry control laboratory and factory laboratories are available for yarn Article qualitative and quantitative analysis purposes
Main Technical Data:
● Measuring count range: 4tex ~ 80ktex.
● Sample Test speed: 4, 8, 25, 51, 100, 200, 400m / min
● Roller start mode: Normal start: 100, 200, 400m / min
Soft start: 4, 8, 25, 50m / min
● length variation curve: Cutting length: 0.01m ~ 100m;
CV% Scope: any;
● statistical variation curve: maximum 24 per group.
● Scale Range of measurement: 100%, 50%, 25%, 12.5%.
● detection timing: 0.5, 1, 1.5, 2, 2.5, 5, 7.5, 10, 25,
50 minutes and so on.
● AF value cutting length range: 4 ~ 5000m.
● defect sensitivity Range of measurement: Details: -30%, -40%, -50%, -60%;
Slub: + 35%, + 50%, + 70%, + 100%;
Cotton Festival: + 140%, + 200%, + 280%, + 400%;
● spectrum Channels: standard type 80 個(gè), fine type 160 個(gè).
● Measuring length: Max 10,000 meters.
● spectral amplification factor setting: Automatic.
● three-dimensional spectrum: Each page can display 12 largest spectrum, up to 24 spectra.
● offset rate (DR%) reference length and limit: 1m + 5%, 1m-5%.
● DR value of the curve: given reference length of 1cm, 10cm, 20cm, 50m, 100cm,
Limit is from 0 to 50% of the positive or negative offset (DR) curve.
● linear density frequency curve: Relative average line density is concerned, can be given from -100% to + 100% of range
Linear density histogram.
● Waveform Analysis: For the current uneven curve, according to 1, 2, 5, 10, 50, 100, 200 meters long pages were
Setting any interception from a certain period.
● uneven curve suppression, half inhibition test: Provides 400 m / min, 200 m / min, 100 m / min, 50 m /
Min, 25 m / min, 8 m / min, 4 m / min are available.
● uneven curve fragment test: 40 meters, 20 meters, 10 meters, 5 meters, 2.5 meters, 1 meter, 50 centimeters,
25 cm, 10 cm, 5 cm optional.
● single-tube / statistical data: to provide a set of tests AF, CV%, U%, CVm (1m, 5m, 10m, 50m, 100m), DR1m (-5%, + 5%) and details (-30% , -40%, -50%, -60%)
Thick section (+ 35%, + 50%, + 70%, + 100%), cotton section (+ 140%, + 200%, + 280%, + 400%), statistics (mean / 1km, S +/-, CVb%, Q95% + / -; mean / kilometers, standard deviation, coefficient of variation between the pipes, 95% confidence interval)
● Statistics function capable of as many varieties of yarn tube statistics, and print the results as required.
● yarn suction device air pressure: 0.05 ~ 0.15Mpa. (Optional)

Back